| |
References
1. “Skin Permeation,” Sontra Medical Corporation, 2002. (PDF)
2. L. Zhang, E. Nolan, S. Kreitschitz, and D. Rabussay, “Enhanced
Delivery of Naked DNA to the Skin by Non-invasive in vivo Electroporation,”
Biochimica et Biophysica Acta, vol. 1572, pp. 1-9, 2002. (PDF)
3. M. R. Prausnitz, “Do High-voltage Pulses Cause Changes in Skin
Structure,” Journal of Controlled Release, vol. 40, pp. 321-326,
1996. (PDF)
4. C. Ionescu-Tirgoviste and S. Pruna, “Non-Invasive Assessment
of Peripheral Dysfunction of the Autonomic Nervous System,” IEEE
Engineering in Medicine and Biology Society. The 10th Annual International
Conference, 1988. (PDF)
5. R. Ivanic, M. Weis, T. Danilla, and V. Tvarozek, “Thin Film Interdigitated
Electrode Arrays Applicable for Non-Invasive Monitoring of Human Skin,”
Advanced Semiconductor Devices and Microsystems. The Third International
EuroConference, pp.319 -322, 2000. (PDF)
6. C.H. Riedel and O. Dossel, “Non-Contact Measurement of the Electrical
Impedance of Biological Tissue,” Engineering in Medicine and Biology
Society. Proceedings of the 23rd Annual International Conference of the
IEEE, vol. 3, pp. 3077-3080, 2001. (PDF)
7. M. Nyren, N. Kuzmina, and L. Emtestam, “Electrical Impedance
as a Potential Tool to Distinguish between Allergic and Irritant Contact
Dermatitis”, Journal of the American Academy of Dermatology, vol.
48, pp. 394-400, 2003. (PDF)
8. C.J. Harland, T.D. Clark, and R.J. Prance, “Remote Detection
of Human Electroencephalograms using Ultrahigh Input Impedance Electric
Potential Sensors,” Applied Physics Letters, vol. 81, no. 17, pp.
3284-3286, 2002. (PDF)
9. A. Caduff, E. Hirt, Y. Feldman, Z. Ali, L. Heinemann, “First
Human Experiments with a Novel Non-Invasive, Non-Optical Continuous Glucose
Monitoring System,” Biosensors and Bioelectronics, vol. 19, pp.
209-217, 2003. (PDF)
10. D.C. Salter, “Quantifying Skin Disease and Healing in vivo using
Electrical Impedance Measurements,” In: Rolfe, P., Ed., Non-Invasive
Physiological Measurements, Medical Physics Series, London: Academic Press,
pp. 21-64, 1979. (PDF)
11. A. Malich, T. Boehm, M. Facius, M.G. Freesmeyer, M. Fleck, R. Anderson,
and W.A. Kaiser, “Differentiation of Mammographically Suspicious
Lesions: Evaluation of Breast Ultrasound, MRI Mammography and Electrical
Impedance Scanning as Adjunctive Technologies in Breast Cancer Detection,”
Clinical Radiology, vol. 56, pp. 278-283, 2001. (PDF)
12. A. Malich, T. Bohm, M. Facius, I. Kleinteich, M. Fleck, D. Sauner,
R. Anderson, and W.A. Kaiser, “Electrical Impedance Scanning as
a New Imaging Modality in Breast Cancer Detection- A Short Review of Clinical
Value on Breast Application, Limitations, and Perspective,” Nuclear
Instruments and Methods in Physics Research A, vol. 497, pp. 75-81, 2003.
(PDF)
13. Y. Glickman, O. Filo, M. David, A. Yayon, M. Topaz, B. Zamir, A. Ginzburg,
D. Rozenman, and G. Kenan, “Electrical Impedance Scanning: A New
Approach to Skin Cancer Diagnosis,” Skin Research and Technology,
vol. 9, pp. 262-268, 2003. (PDF)
|
|